To validate new processes for commercial systems, the processes are first tested in pilot systems. Often the delivery rates are low, ranging between 0.5 to 8 m3/h, and cannot be realised with a reactor pump. For this reason, Egger has developed a pilot pump S that meets all requirements for commercial process pumps. This series has been designed for boundary conditions of 25vol% gas fraction, 100 bar system pressure and a temperature of 280°C.
Applications
Features
| Facts & Figures | |
|---|---|
| Nominal dimensions | DN 15 and DN 25 11⁄2“ and 1” |
| Flow rate | up to 8 m3/h 35 US gpm |
| Differential head | up to 45 m , 150 ft |
| Pressure | up to 100 bar / 1450 psi |
| Temperature | up to 280 °C / 540 °F |
| Material execution | 1.4593, 1.4517, Hastelloy |